Instrument Settings: Leica Total Station

If you have not yet configured total station settings for the project, you are prompted to do so when you select the Total Station survey method.

To configure a total station, in the Home screen tap Setup / TS Settings. The Instrument dialog opens with the following options:

Item Option
Manufacturer Select the manufacturer of the receiver.
Model Tap Model to open a list containing all supported model types. Select the required model.
Connection

Select the medium you want to use for the total station connection: serial or Bluetooth.

Select the correct COM port to use for the connection.

To use a Bluetooth connection, you must first pair the total station with your PC. Use your PC's Bluetooth tool to do this. Once paired, a virtual Bluetooth COM port is configured. Use this one for the connection.

To use the Leica Longrange Bluetooth, you need the TCPS ConfigTool to configure the settings. Contact your dealer if you have any queries.

Remote Trigger

Penmap enables you to take a measurement directly from the instrument, or/and from the Penmap Total Station button.

To active this option, enable the Remote Trigger option box in the total station settings.

When this option is used, Penmap does not use the current line of sight (light blue line) on the survey.

To use this option, select the Q-Survey application (1) from the instrument’s main menu.

To take a measurement you can press F1 (ALL) for Distance and Angle measurements, or press F4 to switch to the second page, then press F1 (DIST) and F2 (REC) for independent distance and angle measurements.

After the first measurement, press Yes (F4) to confirm the message Recording to Interface.

While in Remote Trigger mode you can also fire the instrument using the Total Station button on the Data Collection method bar.

Settings for Leica Total Station Flexline TS02/06/09

If you are using a Leica Total Station Flexline TS02/06/09, configure the following instrument settings:

Instrument Main Menu

  • Settings (5) / General (1) / Page 2/6
    • Set Hz Increment to: Right
    • V Setting to: Zenith
  • Page 3/6
    • Angle unit: °´˝ or gon, dec.deg, mil (Penmap automatically detects the format and converts the values)
  • Page 4/6
    • Set Data output to: Interface
    • Set GSI-Format to: GSI 16
    • Set GSI-Mask to: Mask 1
    • Click OK (F4) to confirm
  • Comm. (3)
    • Set Port to: Bluetooth
    • Set Bluetooth to: Active
    • Check BT PIN (F1): 0000
    • Click OK (F4) to confirm

Before connecting Penmap to a Leica total station for the first time, set the prism constant to “0” (Zero) in the instrument.

After connection to the Leica total station, Penmap transfers a user-defined prism with the prism constant of Penmap to the instrument. The Leica constant is calculated internally.

Do not change the prism type/prism constant directly in the instrument when working with Penmap; otherwise wrong distances are measured and wrong results are calculated.